UF Membrane AQU-90
AQU-90 UF Membrane AQU-90
Ultrafiltration Components Parameters
Model No.
AQU-90PAN
AQU-90PS
AQU-90PP
AQU-90PVDF
Size
L Φ90X1162mm S Φ90X678mm
L Φ90X1162mm S Φ90X678mm
L Φ90X1162mm S Φ90X678mm
L Φ90X1162mm S Φ90X678mm
Hollow fiber material
PAN
PS
PP
PVDF
Hollow fiber ID/OD
1.0mm / 1.6mm
1.0mm / 1.6mm
0.4mm / 0.5mm
0.7mm / 1.3mm
MWCO (Daltons)
50k~100k
10k~100k
50k~100k
100k~200k
Membrane area
L-4.5m2 S-2.3m2
L-4.5m2 S-2.3m2
L-8.9m2 S-4.4m2
L-7.0m2 S-3.4m2
Filtration method
Inside-out
Outside-in
Initial flux L/H, 0.1mpa, 25˚C pure water as feed
>900 (L) >420 (S)
>900 (L) >420 (S)
>1100 (L) >530 (S)
>1000 (L) >480 (S)
Designed water flux
40-120L/m2/h
40-80L/m2/h
End seal material
Epoxy resins
Housing material
UPVC
Connection/Pipe
Union connection / PVC Pipe OD. 32mm
Max. Feed pressure
0.3mpa
0.3mpa
0.3mpa
0.25mpa
Max. trans-membrane pressure
0.2mpa
0.2mpa
0.2mpa
0.15mpa
Normal trans-membrane pressure
0.02-0.15mpa
0.02-0.15mpa
0.02-0.15mpa
0.01-0.1mpa
Feed turbidity
<50ntu
Permeate turbidity
<0.1ntu
Max. working temperature
5-45˚C
PH range
3-9
2-12
1-14
2-13
Microorganism, pathogen
99.99% Removal