Pi²R iX
Full featured & powerful
The Pi²R iX is packed with useful features to enable great power savings.
Features:
-
Separate AC & DC temperature settings
-
Two internal software timers for AC
-
Up to 350Vdc PV input (Voc)
-
Maximum Power Point Tracking (MPPT)
-
PV Power sensor & tracker
Optional via Display:
-
3.5" full color touch LCD
-
Data Logging
-
IoT via WiFi
-
Web APP for Android and Apple
The Pi²R iX can be used with any existing 50-300 Liter geyser as is. Power is fed to the geyser as usual, however temperature is additionally monitored by a separate temperature sensor. The existing thermostat is used to easily connect the power cables, but set to maximum (70° Celsius) to also function as a safety cut-off. An external DB timer is not needed (when used with the optional Display) as the Display automates functionality.
The iX can operate in off-grid installations as it draws power from either Grid or PV for its internal circuitry. The Display also charges from either Grid or PV and has a big enough battery to last through the night. We do however recommend that off-grid installations use an optional higher capacity battery for the display as this will help during winter time when nights are a bit longer.
Technical Specifications
Element Size > 2,3,4 kW
Grid input > 200 - 240Vac, 50-60Hz
PV MPPT > Yes, 15 Amp
PV input > 90* - 350Vdc**
Max PV Power > 320 Vmp @ 15 Amp
Power Sensor > 0-15 Amp DC ±2.5% Tolerance
Dimensions > 125 x 180 x 80mm x 0.75 kg
Operating Temperature > -10 - 55° Celsius
Display charge output1 > 2 - 16Vdc @ 100mA
MTBF > 50,000h
Safety & Protection
AC Disconnect > Yes
Reverse Polarity > Yes, Require external fuse
Over Voltage Category 1 > Yes
Transient Category 1 > 3-Way Surge Arester
EMC Compliant > EN-61326-1
Safety > IEC-60730-1
NRCS > RCC: 2405055
Notes
* 90Vmp minimum recommended
** The element can only handle 320Voc Max, but the iX itself can withstand 350Voc
Frequently asked questions
-
Do the iX/Mocro feed the element with DC?
-
No.
-
The modified wave is safe to controll with the existing thermostat.
-
-
What is the maximum power I can connect to the iX?
-
The important part is to stay below 325Vmp (350Voc) input.
-
240Vmp with a 4kW element is the recommended Maximum.
-
If too much Amps are available, the element will limit itself.
-
-
Why not use 30-40V?
-
Because we feed the standard 230V element, we need a bit higher voltage than our competitors with dedicated low voltage DC element.
-
-
Can I connect panels with more than 15A output?
-
Yes.
-
The iX measures the input current and will limit itself to not draw too much amps.
-
-
My panels are capable of 20A, why is the iX not using all of it?
-
Firstly, the element only draws what it wants on a certain voltage. See power throuhput formula.
Secondly, the iX limits itself to draw only 15A as not to damage its internal components.
-